- Tests on heavy vehicles
- Internal useful capacity : 507 m3 approx
- Internal useful dimensions : 6500x13000x6000 mm (WxDxH)
- Door useful dimensions : 5600x5600 H mm
- Floor capacity : 65 tons (in the full area)
- Temperature range : -55℃/+75℃ (adjustable)
- Temperature accuracy (at steady conditions) : ±1... ±2℃
- Average temperature rate (without internal load) :
- heating up from -55℃ to +75℃ -> 0.5℃/min
- cooling down from +75℃ to -55℃ -> 0.5℃/min
- Climatic range (without any heat load) : +10℃/+75℃
- Humidity range : from 10% to 95% R.H. (adjustable)
- Air velocity (around the specimen) : 0.25 m/sec < V < 1.5 m/sec
- Standard requested : MIL-STD-810F Meth. 501.4 Proc. I & II, Meth. 502.4 Proc. I, II & III, MIL-STD-810F Meth. 507.4